Fast testing, safe operation and low energy consumption
The Seta PM-93 is a fully automated Pensky-Martens closed cup flash point tester, pre-programmed with all major international Pensky-Martens methods including ASTM D93, ASTM D8175, IP 34 and ISO 2719.
Designed for both routine quality control and unknown sample analysis, it operates in expected flash or search mode for maximum flexibility.
A fully motorised lifting head, intuitive touchscreen interface and automated test sequence ensure consistent, repeatable results with minimal operator intervention.
Safety is enhanced through optical fire detection with automatic fire extinguisher, automatic cup lock detection and over-temperature protection, ensuring compliant operation in accordance with ISO 2719 Annex B.
Laboratory efficiency is improved through quick-release components and Seta 'Turbo Cool' technology, enabling rapid cleaning and fast turnaround between tests. An energy-saving standby mode reduces power consumption by up to 40% compared to alternative Pensky-Martens instruments, lowering operating costs and CO2 emissions.
Support and Compliance
Supplied with SETA-0412-0051 Pensky-Martens Flash Point Certified Reference Material 75 °C (pack of 3) >
ASTM D93-25 requires verification using Certified Reference Materials. Seta offers a range of CRMs to support compliance and reliable performance. Learn more about ASTM D93-25 >
For aviation fuel flash point testing, Seta’s Jet A-1 Proficiency Test Scheme supports performance monitoring and ISO 17025 accreditation. View scheme details >
The post PM-93 Pensky-Martens Flash Point Tester - 35000-2 appeared first on Stanhope-Seta.
Precision, accuracy and compliance:
The PM-93 minimises operator influence and ensures consistent, repeatable results through advanced automation and measurement control:
High throughput flash point testing
To maximise laboratory productivity, the PM-93 is designed for fast turnaround and minimal downtime:
Intuitive touchscreen operation
The PM-93 is designed for ease of use, reducing training requirements and simplifying daily operation:
Energy efficiency and low cost of ownership
The PM-93 is the most energy-efficient instrument in its class, designed to reduce operating costs and environmental impact:
Why choose the Seta PM-93?
| # | Наименование новости | Тональность | Информативность | Дата публикации |
|---|---|---|---|---|
| 1 | Introducing the New Seta PM-93 Pensky-Martens Flash Point Tester 35000-2 | 0 | 8.96 | 24-03-2026 |
| 2 | PM-93 Flash Detector - 35000-201 | 0 | 13.6 | 03-03-2026 |
| 3 | Stanhope-Seta Launches the Setaflash CCC Continuously Closed Cup Flash Point Tester Designed for ASTM D6450 and ASTM D7094 Compliant Flash Point Testing | 0 | 3.57 | 23-02-2026 |
| 4 | SetaVap4 Automatic Vapour Pressure Analyser with Digital Density - 80607-2 | 0 | 3.72 | 21-01-2026 |
| 5 | Flash Point Testing in Flavours and Fragrances: Reducing Cost, Improving Safety and Ensuring Compliance | 0 | 5.67 | 23-06-2026 |
| 6 | Fuse 5 A (T) - 19800-704 | 0 | 18.5 | 04-03-2019 |
| 7 | Shouldered Ring (Pack of 10) - 21141-2 | 0 | 16.12 | 21-11-2018 |
| 8 | Анемометр + Термогигрометр + Люксметр «ТКА-ПКМ»(63) | 0 | 15.35 | 10-05-2021 |
| 9 | Продажа бензинов АИ-92, АИ-95 и АИ-100 российское производство. | 0 | 15.32 | 14-06-2026 |
| 10 | Топливо в Севастополе в понедельник поступило в продажу на 14 АЗС сети "Атан" | 0 | 6.32 | 10-08-2026 |